Setting Continue on Source Error During Rebuild

For 9000-series controllers, the Continue on Source Error During Rebuild policy is available for units which are redundant. (For units which are not redundant, this option is not shown on the screen.) When this policy is set, ECC errors are ignored when they are encountered during a rebuild. When this policy is not set, a rebuild will abort upon encountering an ECC error and the unit will be set back to Degraded.

Since enabling this option could result in the loss of some source data in the event of source errors, select this option only if you want to ensure that a rebuild will complete successfully without manually intervention. If the rebuild fails and Continue on Source Error During Rebuild is not selected, then you have the option to start a rebuild manually. It is recommended that a file system check be executed when the rebuild completes.

To set the Continue on Source Error During Rebuild policy

  1. Choose Management > Controller Settings from the menu bar in 3DM.
  2. In the Unit Policies section of the Controller Settings Page, check the boxes to select the policies you want to be in effect for each unit
  3. The page refreshes, and a message at the top confirms the change you have made.